LINX-153
LINX-153 is a LOYTEC product in the Programmable controllers category. ARINN is LOYTEC's Competence Centre in Scandinavia.
Open in ArinnAgora and add to the quote listOpen datasheet (PDF)L-INX / L-GATE User Manual 8.6L-INX Configurator User Manual 8.6
If you do not have a trained technician in-house, ARINN will find a Competence Partner for programming and commissioning. ARINN supports the partner with technical advice and access to LOYTEC.
Description
Automation server for BACnet and CEA-709, programmed in L-STUDIO. KNXnet/IP and Modbus built in; KNX TP1 requires LKNX-300 and M-Bus requires L-MBUS20/80. Has TP/FT-10, 2 × RS-485, 2 EXT ports and L-IOB modules via LIOB-Connect, LIOB-FT and LIOB-IP. BACnet Building Controller (B-BC), BTL-certified.
LOYTEC product text: LINX-153, BACnet & CEA‑709 Automation Server with LIOB‑Connect (No L-LOGICAD support from July 1, 2023)
Courses for this product
- LTRAIN-LSTUDIO
Online modules and 3 days with an instructor
Group C is sold to customers trained and tested by ARINN or LOYTEC. The course and test required are determined by the task. Contact ARINN.
Technical data
| Physical connections | |
|---|---|
| Ethernet | 2 × 100Base-T |
| RS-485 | 2 × RS-485: BACnet MS/TP or Modbus RTU/ASCII (Master or Slave) |
| EXT port | 2 × EXT: M-Bus master EN 13757-3 (needs L-MBUS20 or L-MBUS80) or KNX TP1 (needs LKNX-300) or SMI (needs LSMI-800) |
| CEA-709 TP/FT-10 | 1 × TP/FT-10 (LonMark System); 1 × CEA-709 router |
| LIOB-FT | 1 × LIOB-FT |
| LIOB-Connect | 1 × LIOB-Connect |
| USB | 2 × USB-A |
| KNX TP1 | KNX TP1 via 2 × EXT (needs LKNX-300); each EXT is either M-Bus, KNX TP1 or SMI |
| M-Bus | M-Bus master EN 13757-3 via 2 × EXT (needs L-MBUS20 or L-MBUS80); each EXT is either M-Bus, KNX TP1 or SMI |
| MP-Bus | via USB accessory LMPBUS-804 |
| SMI | via EXT (needs LSMI-800) or USB (needs LSMI-804) |
| I/O | |
| L-IOB expansion | LIOB-Connect, LIOB-FT, LIOB-IP; up to 24 L-IOB modules |
| Protocols and wireless | |
| BACnet | BACnet/IP, BACnet/SC, BACnet MS/TP; 1 × BACnet/IP router; BTL certified |
| Modbus | Modbus TCP (Master or Slave), Modbus RTU/ASCII (Master or Slave) |
| OPC | OPC XML-DA, OPC UA |
| KNXnet/IP | KNXnet/IP |
| EnOcean | via USB accessory LENO-80x |
| WLAN | via USB accessory LWLAN-800 |
| Programming | |
| Programmable | L-STUDIO (IEC 61131-3 and IEC 61499 based); L-STUDIO license included |
| Configured in | L-INX Configurator |
| IoT (Node.js) | Node.js |
| Physical | |
| Display | 128 × 64 graphic display with backlight |
| Supply | 24 V DC / V AC SELV ±10 % (via L-POW or external power supply) |
| Power | typ. 2.5 W |
| Dimensions (mm) | 159 × 100 × 75 mm (L × W × H), 9 DU |
| Mounting | DIN rail (DIN 43880, EN 50022) |
| Capacity | |
| Total data points | 30 000 |
| BACnet objects | 2 000 (analog, binary, multi-state) |
| BACnet client mappings | 5 000 |
| Trend logs | 512 (13 000 000 entries, ≈ 200 MB) |
| Schedulers | 100 BACnet scheduler objects (64 data points per object); 100 LonMark Schedulers |
| Alarms | 32 BACnet notification classes; 1 LonMark Alarm Server; 10 alarm logs |
| Concurrent L-WEB clients | 32 (simultaneously) |
| Room segments | 8 |
Taken from datasheet Datasheet_LINX-153_LINX-154.pdf. Hover over a value to see the page. In case of discrepancy, the datasheet applies.